Isolate
the top and bottom of wood or steel Stud Partition
with Iso-sill and Iso-sill Anchor Isolators (Model
ISW)
Concrete Partitions, poured or block can be isolated
as well. (observe maximum
loadings).
ISO-SILL
acoustic isolation pads acts like
a permanently resilient gasket used to reduce sound
and vibration transfer through the building structures.
Iso-sill can be used for wood and steel framing, or
for concrete block or pour.
Iso-sill
is manufactured with re-claimed rubber and is formulated
with high damping acrylic polymers making it a “Green”
product for LEED projects.
The Iso-sill pad is manufactured to carefully controlled
density standards for trusted long term service.Iso-sill
is impervious to water, most chemicals and temperature
change. Iso-sill will not rot or support mold.
Iso-sill can be installed with mechanical fasteners,
polyurethane based construction adhesives, or a variety
of thin-sets and mortars. Iso-sill anchor washers
are available.
|
|
•
Factory slit to width and easily field cut to length
with utility knives.
•
Unlike fiberglass it is not affected by moisture.
•
Used for both top and bottom plates.
•
Can be used for a wide range of loadings
(1-50 psi).
•
Continuous resilient support of partition.
•
Unaffected by water.
•
Will not support mold growth.
|
•
Can use mechanical fasteners or adhesives (PSA
available).
•
Iso-sill is available in thicknesses of either 5 mm
or 10 mm. It is provided slit to required widths.
•
Standard sizes are 1.25”, 1.5”, 3.5”,
5.5” and 8” + custom widths.
•
Model IS / 5 or 10 (indicates
thickness) 3.5
(indicates
width).
•
Iso-sill anchor washers standard 1-1/4”
dia., 91/16” thick. |
| •
Flanking of sound and structure borne vibration can
significantly de-rate sound rated partitions for both
wall and floor/ceiling assemblies.
•
Both STC (airborne) and IIC (impact noise) can be affected
by more than 10 points as compared to non-flanked
assemblies.
•
AcoustiGuard’ Model Iso-sill Acoustic Isolation
Pad offers an easy and in-expensive solution for resiliently
decoupling sound rated assemblies from other parts of
the structure.
•
Iso-sill effectively breaks the connection between rated
and non-rated assemblies resiliently isolating
sound and vibration.
•
Iso-sill remains permanently elastic and is unaffected
by water.
•
Iso-sill is used in continuous strips on both top and
bottom plates to ensure the sound rated assembly
will be decoupled and remain fully effective.
•
Isolated anchors washers (Model ISW) are used to isolate
fasteners.
back